Common faults of the hottest engraving machine

2022-08-15
  • Detail

Common faults of engraving machine

I: one or three axes do not move or move abnormally

1: the control card is loose or faulty

2: the driver of the corresponding axis fails

3: corresponding axis stepper motor fault

4: the corresponding coupling is broken or loose

5: the corresponding screw rod is broken or the screw nut is faulty

6: the sliding of the corresponding shaft and pressing the "pin retraction" button will soon cause failure

7: the subdivision and current of the driver are different from those set in the software

II: z-axis out of control

1: the control card is loose or faulty

2: electrostatic interference

3: file path error

4: frequency converter interference

5: there is a problem or virus in the computer system

6: operation error

III: error

1: loose or faulty control card

2: driver fault

3: stepper motor fault

4: electrostatic interference

5: related line fault

6: data line fault

7: wrong path

8: broken or loose coupling

9: too fast processing speed

1 0: computer system problems or viruses

IV: different engraving depths

1: loose or faulty control card Fault

2: step motor fault

3: driver fault or current subdivision is inconsistent with software settings

4: z-axis line fault

5: spindle motor fault

6: frequency converter interference or data setting error

7: electrostatic interference

8: computer virus or system problems

V: random engraving

enhance quality awareness 1: control card fault

2: frequency converter interference

3: the file path is incorrect

4: electrostatic drying Disturbance

5: there is a problem with the software setting

6: the driver is faulty or the current subdivision setting is incorrect

7: the data line is faulty

8: the computer has a virus or system problem

6: the bottom is uneven

1: the spindle is not perpendicular to the table. Need to be corrected

2: there is a problem with the tool

3: there is a problem with the control card

7: the spindle stops rotating

1: the internal short circuit of the spindle

2: current shielding

3: the parameter setting of the frequency converter can apply a certain initial load F0 (corresponding to 5% ~ 10% of the elastic deformation load) to the sample is wrong or its own fault

4: the fault of the control card

5: the stretching, tightening space and stretching of the spindle line, namely the experiment Tight space width or data line short circuit

VIII: the spindle rotation sound is abnormal

1: the frequency converter is set incorrectly

2: the spindle does not rotate

3: the spindle itself has a problem

IX: the machine cannot return to the mechanical origin normally

1: the direction is opposite

2: the control card is faulty or loose

3: the limit switch or data line is faulty

4: the driver is faulty

5: the step motor.Fault

X: automatic rotation or stop of spindle No

1: control card fault

2: inverter fault (end)

Copyright © 2011 JIN SHI